54

Motor Nameplate Data

Figure 8 Flux Vector

Motor Nameplate
Data

These parameters provide motor information to the drive, so the drive can both
protect the motor and also make internal adjustments to provide the best
performance.

[Motor NP Volts]
The rated voltage as stated on the motor nameplate.

[Motor NP FLA]
The rated full load amps as stated on the motor nameplate.

[Motor NP Hz]
The rated base frequency as stated on the motor nameplate.

[Motor NP RPM]
The rated base speed in RPM as stated on the motor nameplate.

[Motor NP Power]
The rated power as stated on the motor nameplate. This may be entered in
horsepower or in kilowatts as selected in [Mtr NP Pwr Units], parameter 46.

[Mtr NP Pwr Units]
Determines the units for [Motor NP Power]. Possible settings are:

0 “Horsepower” - units are displayed in HP.

1 “kilowatts” - units are displayed in kW.

2 “Convert HP” - converts units to HP (from kW) by dividing [Motor NP
Power] by 0.746 (PowerFlex 700VC Only).

3 “Covert kW” - converts units to kW (from HP) by multiplying [Motor NP
Power] by 0.746 (PowerFlex 700VC Only).

[Motor Poles]
Defines the number of poles in the motor. [Motor Poles] is calculated automatically
if the user enters the motor nameplate data through the Assisted Start-up menu of
an LCD HIM. The number of motor poles is defined by:

Adaptive

Controller

High Bandwidth Current Regulator

SPEED REF.

TORQUE REF.

SLIP

SPEED FEEDBACK

CURRENT FEEDBACK

AUTOTUNE PARAMETERS

V mag

V ang

Current

Reg.

Speed

Reg.

Flux

Reg.

Voltage

Control

Inverter

Motor

Encoder

70EC

700VC

700H

✔ ✔

where:
P = motor poles
f = base motor frequency (Hz)
N = synchronous RPM at base motor frequency (f)

P

120f

N

---------

=