beautypg.com

B - configuring the star configuration, Appendix b, Configuring the star configuration – Rockwell Automation 1756-SYNCH ControlLogix SynchLink Module User Manual User Manual

Page 77: E appendix b, Star configuration - appendix b - t, E appendix b for an example, Appendix

background image

1

Publication 1756-UM521C-EN-P - July 2004

Appendix

B

Configuring the Star Configuration

This appendix describes how to configure the ControlLogix SynchLink
module in a Star configuration using remote axis control. In this example
configuration, the following occurs:

• The controller in the Time Master chassis produces axis data.
• The axis data is transmitted via SynchLink modules to each Time Slave

chassis.

• The controller in each Time Slave chassis consumes the axis data.

The system’s physical configuration is shown in Figure B.1. In this
configuration, you must:

• configure the Master Node in an RSLogix 5000 project.
• configure each End Node in separate RSLogix 5000 projects.

Figure B.1

42882

Master Node

ControlNet

SynchLink

End Node

Hub

End Node

The SynchLink module in
this chassis is configured
as the Time Master for
the SynchLink.

The SynchLink modules in these chassis are configured as
the CST Time Masters and SynchLink Time Slaves.