Rockwell Automation 1791DS-IBxxxx Guard I/O DeviceNet Safety Modules User Manual
Page 154
154
Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013
Appendix A
Get Point Status from Modules by Using Explicit Messaging
364
(868)
1732DS-IB8, 1732DS-
IB8XOBV4, 1791DS-
IB8XOBV4
0
Safety Input
7
Safety Input 6 Safety Input
5
Safety Input 4 Safety Input
3
Safety Input 2 Safety Input 1
Safety Input 0
1
Safety Input
7 Status
Safety Input 6
Status
Safety Input
5 Status
Safety Input 4
Status
Safety Input
3 Status
Safety Input 2
Status
Safety Input 1
Status
Safety Input 0
Status
2
Test Output 7
Status
Test Output 6
Status
Test Output 5
Status
Test Output 4
Status
Test Output 3
Status
Test Output 2
Status
Test Output 1
Status
Test Output 0
Status
3
Reserved
Muting Lamp 7
Status
Muting Lamp 3
Status
365
(869)
1791DS-IB16
0
Standard
Output 7
Standard
Output 6
Standard
Output 5
Standard
Output 4
Standard
Output 3
Standard
Output 2
Standard
Output 1
Standard
Output 0
1
Standard
Output 15
Standard
Output 14
Standard
Output 13
Standard
Output 12
Standard
Output 11
Standard
Output 10
Standard
Output 9
Standard
Output 8
2
Safety Input
7 Status
Safety Input 6
Status
Safety Input
5 Status
Safety Input 4
Status
Safety Input
3 Status
Safety Input 2
Status
Safety Input 1
Status
Safety Input 0
Status
3
Safety Input
15 Status
Safety Input
14 Status
Safety Input
13 Status
Safety Input
12 Status
Safety Input
11 Status
Safety Input
10 Status
Safety Input 9
Status
Safety Input 8
Status
4
Test Output 7
Status
Test Output 6
Status
Test Output 5
Status
Test Output 4
Status
Test Output 3
Status
Test Output 2
Status
Test Output 1
Status
Test Output 0
Status
5
Test Output
15 Status
Test Output
14 Status
Test Output
13 Status
Test Output
12 Status
Test Output
11 Status
Test Output
10 Status
Test Output 9
Status
Test Output 8
Status
6
Reserved
Reserved
Reserved
Reserved
Muting Lamp
15 Status
Muting Lamp
11 Status
Muting Lamp 7
Status
Muting Lamp 3
Status
374
(884)
1732DS-IB8XOBV4,
1791DS-IB8XOBV4
0
Safety Input
7
Safety Input 6 Safety Input
5
Safety Input 4 Safety Input
3
Safety Input 2 Safety Input 1
Safety Input 0
1
Safety Input
7 Status
Safety Input 6
Status
Safety Input
5 Status
Safety Input 4
Status
Safety Input
3 Status
Safety Input 2
Status
Safety Input 1
Status
Safety Input 0
Status
2
Safety
Output 7
Status
Safety Output
6 Status
Safety
Output 5
Status
Safety Output
4 Status
Safety
Output 3
Status
Safety Output
2 Status
Safety Output 1
Status
Safety Output
0 Status
3
Safety Output
7 Readback
Safety Output
6 Readback
Safety
Output 5
Readback
Safety Output
4 Readback
Safety Output
3 Readback
Safety Output
2 Readback
Safety Output 1
Readback
Safety Output 0
Readback
4
Test Output 7
Status
Test Output 6
Status
Test Output 5
Status
Test Output 4
Status
Test Output 3
Status
Test Output 2
Status
Test Output 1
Status
Test Output 0
Status
5
Reserved
Muting Lamp 7
Status
Muting Lamp 3
Status
384
(900)
1732DS-IB8
0
Reserved
Input Power
Error
1
Test Output 7
Status
Test Output 6
Status
Test Output 5
Status
Test Output 4
Status
Test Output 3
Status
Test Output 2
Status
Test Output 1
Status
Test Output 0
Status
385
(901)
1791DS-IB16
0
Reserved
Input Power
Error
1
Test Output 7
Status
Test Output 6
Status
Test Output 5
Status
Test Output 4
Status
Test Output 3
Status
Test Output 2
Status
Test Output 1
Status
Test Output 0
Status
2
Test Output
15 Status
Test Output
14 Status
Test Output
13 Status
Test Output
12 Status
Test Output
11 Status
Test Output
10 Status
Test Output 9
Status
Test Output 8
Status
Table 20 - Input Data for 1732DS-IB8, 1732DS-IB8XOBV4, 1791DS-IB8XOBV4, 1791DS-IB16 Modules (continued)
Instance Hex
(decimal)
Module
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0