Starter approximate dimensions – Rockwell Automation 193-EC4 EC4 Current Monitoring Relay User Manual User Manual
Page 19

20
Rockwell Automation Publication 193-UM011A-EN-P - September 2010
Chapter 2 Installation and Wiring
Starter Approximate Dimensions
Approximate dimensions are shown in millimeters (inches). Dimensions are not
intended to be used for manufacturing purposes.
Figure 5 - Bulletin 109 Approximate Starter Dimensions
A
A
D2
D2
D1
D1
F1
F1
E2
E2
B1
B1
B
1
E
ØD
H
C
Table 1 - Bulletin 109 Approximate Starter Dimensions
Overload Cat.
No.
Contactor
Cat. No.
Width A
Height B
B1
Depth C
E1
E2
without
193-EIMD
with 193-EIMD
193-EC_ _B
100-C09, -C12
-C16, -C23
45 (1-25/32)
188.3 (7-13/32)
207.7 (8-11/64)
145.1
(5-23/32)
107 (4-7/32)
11.4 (29/64)
67.9
(2-43/64)
193-EC_ _D
100-C30, -C37
45 (1-25/32)
188.3 (7-13/32)
207.7 (8-11/64)
145.1
(5-23/32)
107 (4-7/32)
11.4 (29/64)
67.9
(2-43/64)
193-EC_ _D
100-C43
54 (2-1/8)
188.3 (7-13/32)
207.7 (8-11/64)
145.1
(5-23/32)
107 (4-7/32)
11.4 (29/64)
67.9
(2-43/64)
193-EC_ _E
100-C60, -C72,
-C85
72 (2-53/64)
236.1 (9-19/64)
255.5 (10-1/16)
173.2
(6-13/16)
124.6
(4-29/32)
11.4 (29/64)
89.8
(3-17/32)
Overload Cat.
No.
Contactor Cat. No.
F1
D1
D2
H
J
ØD
193-EC_ _B
100-C09, -C12 -C16,
-C23
53.2 (2-3/32)
60 (2-23/64)
35 (1-3/8)
85.1 (3-23/64)
2 (5/64)
Ш4.2 (11/64Ш)
193-EC_ _D
100-C30, -C37
53.2 (2-3/32)
60 (2-23/64)
35 (1-3/8)
104 (4-3/32)
2 (5/64)
Ш4.2 (11/64Ш)
193-EC_ _D
100-C43
62.2 (2-7/16)
60 (2-23/64)
45 (1-25/32)
107 (4-7/32)
2 (5/64)
Ш4.2 (11/64Ш)
193-EC_ _E
100-C60, -C72, -C85
80.2 (3-9/64)
100 (3-15/16)
55 (2-11/64)
125.5 (4-15/16)
2 (5/64)
Ш5.5 (7/32Ш)