Rockwell Automation 193-EC4 EC4 Current Monitoring Relay User Manual User Manual
Page 131

132
Rockwell Automation Publication 193-UM011A-EN-P - September 2010
Appendix B DeviceNet Information
The following instances 5…7 (Group 3 Explicit Message Connections Allocated
through UCMM) are supported:
The following common services are implemented for the Connection Object:
12
Get/Set
Watchdog Action
USINT
0 = Transition to timed out
1 = Auto delete
2 = Auto reset
13
Get
Produced Connection
Path Length
UINT
8
14
Get/Set
Produced Connection
Path
EPATH
21 04 00 25 (assy. inst.) 00 30 03
15
Get
Consumed Connection
Path Length
UINT
8
16
Get/Set
Consumed Connection
Path
EPATH
21 04 00 25 (assy. inst.) 00 30 03
Table 38 - Connection Object Instances 5…7 Attributes
Attribute
ID
Access
Rule
Name
Data
Type
Value
1
Get
State
USINT
0 = Nonexistent
1 = Configuring
3 = Established
4 = Timed out
2
Get
Instance Type
USINT
0 = Explicit Message
3
Get
Transport Class Trigger
BYTE
0x83 — Server, Transport Class 3
4
Get
Produced Connection ID
UINT
Depends on message group
and message ID
5
Get
Consumed Connection ID
UINT
Depends on message group
and message ID
6
Get
Initial Comm
Characteristics
BYTE
0x33 (Group 3)
7
Get
Produced Connection Size UINT
0
8
Get
Consumed Connection
Size
UINT
9
Get/Set
Expected Packet Rate
UINT
in ms
12
Get
Watchdog Action
USINT
01 = Auto delete
03 = Deferred delete
13
Get
Produced Connection
Path Length
UINT
0
14
Get
Produced Connection
Path
Empty
15
Get
Consumed Connection
Path Length
UINT
0
16
Get
Consumed Connection
Path
Empty
Table 37 - Connection Object Instance 4 Attributes
Attribute
ID
Access
Rule
Name
Data
Type
Value