Electromagnetic compatibility specifications, Functionality specifications protection – Rockwell Automation 193-EC4 EC4 Current Monitoring Relay User Manual User Manual
Page 120

Rockwell Automation Publication 193-UM011A-EN-P - September 2010
121
Specifications Appendix A
Electromagnetic
Compatibility
Specifications
➊Performance Criteria 1 requires the DUT to experience no degradation or loss of performance.
➋Environment 2.
Functionality
Specifications
Protection
Table 7 - Electromagnetic Compatibility Specifications
Electrostatic Discharge Immunity
Test Level:
Performance Criteria:
8kV Air Discharge
6kV Contact Discharge
1 ➊➋
RF Immunity
Test Level:
Performance Criteria:
10V/m
1 ➊➋
Electrical Fast Transient/Burst Immunity
Test Level:
Performance Criteria:
4kV (Power)
2kV (Control & Comm)
1 ➊➋
Surge Immunity
Test Level:
Performance Criteria:
2kV (L-E)
1kV (L-L)
1 ➊➋
Radiated Emissions
Class A
Conducted Emissions
Class A
Table 8 - DeviceNet Communications
Baud Rate
125 k, 250 k, 500 k
Auto-Baud Rate Identification
Yes
“Group 2 – Slave Only” device type
Yes
Polled I/O Messaging
Yes
Change of State Messaging
Yes
Cyclic Messaging
Yes
Explicit Messaging
Yes
Full Parameter Object Support
Yes
Group 4 – Off-Line Node Recovery Messaging
Yes
Configuring Consistency Value
Yes
Unconnected Messaging Manager (UCMM)
Yes
Table 9 - Protection
Trip Warning
Undercurrent
Yes
Yes
Overcurrent
Yes
Yes
Line Loss
Yes
Yes