Safe speed monitor option module – Rockwell Automation 21G PowerFlex 750-Series AC Drives User Manual
Page 247
![background image](/manuals/577696/247/background.png)
Rockwell Automation Publication 750-IN001N-EN-P - April 2014
247
PowerFlex 750-Series AC Drives
Safe Speed Monitor Option Module
The Safe Speed Monitor option is just one component in a safety control system.
Components in the system must be chosen and applied appropriately to achieve
the desired level of operational safety. For detailed information on applying this
option, refer to the Safe Speed Monitor Option Module for PowerFlex 750-
Series AC Drives Safety Reference Manual, publicat
.
Table 64 - TB1 Terminal Designations
Table 65 - TB2 Terminal Designations
20-750-S1
Terminal
Name
Signal Name
Description
S11
Pto0
TEST_OUT_0
Pulse test source for safety inputs.
S11
S11
S21
Pto1
TEST_OUT_1
Pulse test source for safety inputs.
S21
S21
Terminal
Name
Description
Related
Param
S34
Res0
Reset
52
Dco1
Door Control Output.
Enables pulse testing.
74
51
Dco0
78
Slo1
Safe Limited Speed Output.
Enables pulse testing.
73
68
Slo0
44
Sso1
Safe Stop Output.
Enables pulse testing.
72
34
Sso0
X42
Lmi1
Lock Monitoring Input
60
X32
Lmi0
S42
Dmi1
Door Monitoring Input
58
S32
Dmi0
S62
Sli1
Safe Limited Speed Input
52
S52
Sli0
S82
Esm1
Enabling Switch Monitoring Input
54
S72
Esm0
S22
Ssi1
Safe Stop Input
44
S12
Ssi0
A2
24VC
Customer supplied 24V DC. Module is not functional
without these connections.
A1
+24V
S11
S11
S11
S21
S21
S21
S34
52
51
78
68
44
34
X42
X32
S42
S32
S62
S52
S82
S72
S22
S12
A2