Catalog number explanation (continued) – Rockwell Automation 21G PowerFlex 750-Series AC Drives User Manual
Page 10

10
Rockwell Automation Publication 750-IN001N-EN-P - April 2014
PowerFlex 750-Series AC Drives
Catalog Number Explanation (continued)
f3
f4
g
h
i
PowerFlex 755 w/Options (21G)
Required Selections
PowerFlex 755 w/Options (21G)
Additional Selections
ND Rating
600V, 60 Hz Input
Code
Amps
Hp
Frame
Enclosure Code
B, J,
L, T
F
G
N
K, P,
W, Y
R
1P7
1.7
1
–
3
3
3
–
–
2P7
2.7
2
3P9
3.9
3
6P1
6.1
5
9P0
9
7.5
011
11
10
012
(1)
(1)
Required for uncontrolled common DC bus applications. Optional
for all AC applications.
12
10
–
6
6
017
17
15
3
3
3
018
18
15
–
6
6
022
22
20
3
3
3
023
23
20
–
6
6
024
24
20
027
27
25
4
4
4
028
28
25
–
6
6
032
32
30
4
4
4
033
33
30
–
6
6
041
41
40
5
5
5
042
42
40
–
6
6
052
52
50
5
–
5
053
53
50
(2)
(2)
For Frames 6…7 a user installed Flange kit (20-750-FLNG4-Fx) is
available to convert a Code N drive that provides a NEMA/UL Type
4X/12 back.
6
6
063
63
60
077
77
75
099
99
100
125
125
125
144
144
150
192
192
200
7
7
242
242
250
289
289
300
295
295
300
8
–
–
–
8
(3)
(3)
Available as a drive with options (21G).
355
355
350
395
395
400
435
435
450
460
460
500
510
510
500
595
595
600
9
9
630
630
700
760
760
800
825
825
900
900
900
950
980
980
1000
1K1
1110
1100
10
10
1K4
1430
1400
ND Rating
690V, 50 Hz Input (not UL listed)
Code
Amps
kW
Frame
Enclosure Code
B, J,
L, T
F
G
N
K, P,
W, Y
R
012
12
7.5
–
(1)
(1)
For Frames 6…7 a user installed Flange kit (20-750-FLNG4-Fx) is
available to convert a Code N drive that provides a NEMA/UL Type
4X/12 back.
6
6
–
–
015
15
11
020
20
15
023
23
18.5
030
30
22
034
34
30
046
46
37
050
50
45
061
61
55
082
82
75
098
98
90
119
119
110
142
142
132
171
171
160
7
7
212
212
200
263
263
250
265
265
250
8
–
–
8
(2)
(2)
Available as a drive with options (21G).
330
330
315
370
370
355
415
415
400
460
460
450
500
500
500
590
590
560
9
–
9
650
650
630
710
710
710
765
765
750
795
795
800
960
960
900
1K0
1040
1000
10
1K4
1400
1400
Filtering and CM Cap Configuration
(1)
(1) 480V drives must select code “A.” Jumpers are included for field re-
configuration as desired.
Code
Filtering
Default CM Cap Connection
A
Yes
Jumper Removed
J
Yes
Jumper Installed
Dynamic Braking
(1)
(1)
Not available on Frames 8…10, specify Code “N.”
Code
Internal Resistor
(2)
(2)
Frames 1…2 only. Internal Resistor kits (20-750-DB1-Dx) sold
separately.
Internal Transistor
(3)
(3)
Standard on Frames 1…5, optional on 6…7.
A
No
Yes
N
No
No
Door Mounted HIM (Frames 8…10)
Code
Operator Interface
0
No Door Mounted HIM
2
Enhanced LCD, Full Numeric, IP20
4
Enhanced LCD, Full Numeric, IP66 NEMA Type 4X/12
Code
Option
Frames
Type
LD
Light Duty
8…10
System Overload
Duty Cycle
(1)
(1)
Only one option of this type ma y be selected.
ND
Normal Duty
HD
Heavy Duty
P3
Input Thermal Magnetic
Circuit Breaker
8…10
Power
Disconnect
P5
Input Non-Fused Molded
Case Disconnect Switch
8 Only
P14
Wiring Only Bay
8…10
Wiring Only Bay
Code
Option
Frames
Type
P11
Input Contactor
8 Only
Contactors
(1)(2)
(1)
Only one option of this type ma y be selected.
(2)
Contactor options are not available for systems with MCC power
bus.
P12
Output Contactor
L1
3% Input Reactor
8…9
Reactors
L2
3% Output Reactor
L3
5% Input Reactor
8 Only
L4
5% Output Reactor
P20
1200 Amp Bus
8…10
MCC Power Bus
Capacity
P22
2000 Amp Bus
P24
3000 Amp Bus
P30
UPS Control Bus, DC Input
w/Precharge only
8…10
UPS Control Bus
X1
Auxiliary Transformer
(500VA available), IP20
Cabinet Only
8 Only
(3)
(3)
Standard on all other cabinet configurations.
Auxiliary Power
1…3
4
5
6
7
8…10
11
12
13
14
15
16
17
18
20G 1
A
N
D
248
A
A
0
N
N
N
N
N
-LD-P3-P11…
a
b
c
d
e
g
h
i
f1…f4
Cabinet Options (21G)