Rockwell Automation 21G PowerFlex 750-Series AC Drives User Manual
Page 166
166
Rockwell Automation Publication 750-IN001N-EN-P - April 2014
PowerFlex 750-Series AC Drives
690 V
olt A
C and 932V DC Input Pr
ot
ec
tion Devic
es - W
all
Mount F
rames 6…7
Ap
pli
ed
Ra
ting
(1
)
Frame
Co
nt
.
Ou
tp
u
t
Amps
Dr
iv
e Si
ze
d
F
or
N
or
m
al
Du
ty
D
ri
ve
Si
ze
d
F
or
H
ea
vy
Du
ty
Cont
inu
ous
AC
In
pu
t
AC
Inp
ut Protec
ti
on D
evi
ces
In
put
Q
ua
n
ti
ti
es
DC I
n
pu
t
Protec
tion
Ca
talo
g
Nu
mb
er
Out
p
u
t Ov
er
lo
ad
A
m
ps
Ca
ta
lo
g
N
u
m
be
r
Ou
tp
u
t Ov
er
lo
ad
A
m
ps
Du
al
E
le
m
en
t
Tim
e Dela
y F
u
se
Non-
Time Dela
y
Fuse
Ci
rc
u
it
Break
er Max
Si
ze
(6
)
Motor
Circuit
Prote
ctor
(7
)
Co
ntinuo
us D
C
In
put
Non-
Time Dela
y
Fuse
(x = F
or
G
)
1 min
3 sec
(x = F or G)
1 min
3 sec
Amps
M
in
(2)
Ma
x
(5)
Mi
n
(2)
Ma
x
(5)
Amps
690
V
olt
AC
Inp
u
t
932
V
olt DC Input
5.5
kW
6
9
20
x…F01
1
13
.5
18.0
8.4
11
19
11
25
30
15
9.9
HSJ15
7.5
kW
6
12
20x…F0
11
13.2
18.0
20
x…F01
5
18.0
22.5
11.2
14
25
14
35
40
15
13.2
H
SJ
20
11
kW
6
15
20
x…
F01
5
16.5
22.5
20
x…F02
0
22
.5
30.0
14.1
18
32
18
40
50
20
16
.5
HSJ25
15
kW
6
20
20x…F0
20
22.0
30.0
20
x…F02
3
30.0
36.0
18.7
23
42
23
55
60
25
21.9
H
SJ
35
18
.5 kW
6
23
20
x…
F02
3
25.3
34.5
20
x…F03
0
34
.5
45.0
21.6
27
(3)
, 25
(4)
48
(3)
, 50
(4)
27
(3)
, 25
(4)
65
70
30
25
.2
HSJ40
22
kW
6
30
20x…F0
30
33.0
45.0
20
x…F03
4
45.0
54.0
28.1
35
65
35
85
90
40
32.9
H
SJ
50
30
kW
6
34
20
x…
F03
4
37.4
51.0
20
x…F04
6
51
.0
69.0
31.9
40
70
40
95
10
0
40
37
.3
HSJ60
37
kW
6
46
20x…F0
46
50.6
69.0
20
x…F05
0
69.0
82.8
43.1
55
95
55
13
0
13
0
55
50.5
H
SJ
80
45
kW
6
50
20
x…
F05
0
55.0
75.0
20
x…F06
1
75
.0
91.5
46.9
60
105
60
14
0
15
0
60
54
.8
HSJ90
55
kW
6
61
20x…F0
61
67.1
91.5
20
x…F08
2
91.5
123.0
57.2
70
130
70
17
0
18
0
75
66
.9
HSJ
100
75
kW
6
82
20
x…
F08
2
90.2
123
.0
20
x…F09
8
123.0
147.6
76.8
95
175
95
23
0
24
0
10
0
89
.9
HSJ150
90
kW
6
98
20x…F0
98
107
.8
147
.0
20
x…F11
9
147.0
178.5
91.8
115
205
11
5
27
5
28
0
11
5
107.5
H
SJ
175
11
0 kW
6
11
9
20
x…
F11
9
130
.9
178
.5
20
x…F14
2
178.5
214.2
111
.5
14
0
250
14
0
33
5
34
0
14
0
130.5
HSJ200
13
2 kW
6
142
20x…F1
42
156
.2
213
.0
133
.1
165
300
165
40
0
40
0
17
0
155.7
H
SJ
250
7
14
2
20
x…F17
1
213.0
256.5
133
.1
16
5
300
16
5
40
0
40
0
17
0
155.7
HSJ250
16
0 kW
7
171
20x…F1
71
188
.1
256
.5
20
x…F21
2
256.5
318.0
160
.2
200
360
200
48
0
49
0
20
5
187.5
H
SJ
300
20
0 kW
7
21
2
20
x…
F21
2
233
.2
318
.0
20
x…F26
3
318.0
394.5
198
.7
25
0
445
25
0
59
5
60
0
25
0
232.5
HSJ350
25
0 kW
7
263
20x…F2
63
289
.3
394
.5
246
.5
310
555
310
74
0
74
0
31
0
288.4
H
SJ
500
(1)
“Ap
plied Rating
” r
efers
to
the mot
or tha
t w
ill
b
e connec
ted
to the d
riv
e.
F
or exam
pl
e,
a “F0
61” dr
iv
e c
an b
e us
ed i
n Norma
l D
ut
y m
od
e
on
a5
5 k
W
mo
to
r, i
n Heav
y
D
ut
y
mo
de
o
n a
4
5
kW
m
oto
r. Th
e d
rive c
an
b
e p
ro
gra
mm
ed
fo
r ea
ch
m
od
e.
W
iri
ng
a
nd
fu
se
s
ca
n be
siz
ed
based
o
n the pr
ogr
ammed mod
e.
F
or an
y giv
en
driv
e c
atalog number
, N
ormal D
ut
y mod
e pr
ov
ides higher c
ontinuous cu
rr
en
t but small
er ov
er
lo
ad
curr
ent w
ith r
es
pe
ct to Hea
vy D
ut
y m
ode
. S
ee p
ar
ame
ter 30
6 [D
ut
y R
ati
ng]. R
efer
to S
pec
ific
at
io
ns for an expl
anatio
n of
Du
ty
Ra
tin
gs
.
(2)
M
inimum pr
ot
ec
tion devic
e siz
e is th
e l
ow
est ra
ted d
evi
ce
that sup
pl
ie
s m
ax
imum p
rot
ec
tion without nuisance trip
ping
.
(3)
N
orma
l dut
y.
(4)
H
ea
vy
dut
y.
(5)
M
aximum pr
ot
ec
tion devic
e siz
e is the hi
ghest r
at
ed devic
e tha
t sup
plies
driv
e pr
ot
ec
tion
. F
or U
S N
EC
, mi
nim
um si
ze
is
12
5%
of
motor FL
A. R
ating
s shown are ma
xi
mum
.
(6)
Circui
t B
rea
ke
r -
in
ve
rse
ti
m
e br
ea
ke
r. F
or U
S NEC, m
ini
mu
m s
iz
e is
1
25%
of
motor FL
A. R
ating
s s
hown are m
axi
m
um.
(7)
Rec
ommended Mot
or cir
cuit p
rot
ec
tor - Instan
taneous trip cir
cuit br
eak
er
. T
he trip setting
sh
ould
be set t
o the in
put curr
en
t of
the
driv
e and should be sized for the con
tinuo
us c
urr
ent
of
the syst
em
.