EAGLE 2 Operator’s Manual
Using Setup Mode • 117
1. From the main menu, place the cursor next to ALARM LATCHING.
2. Press and release POWER ENTER RESET. The Alarm Latching Screen
appears.
3. Use AIR ▲ YES or RANGE ▼ SHIFT to display the desired setting.
4. Press and release POWER ENTER RESET to save the setting and return
to the main menu.
Updating the Alarm Silence Setting
With ALARM SILENCE set to ON (factory setting), pressing and releasing
any button silences the buzzer when the EAGLE 2 is in alarm. The LEDs
continue to flash and the display continues to show the alarm. When the gas
concentration falls below the alarm level, pressing and releasing POWER
ENTER RESET clears all alarm indications for that alarm. If an alarm
condition occurs, you may still enter Display Mode by pressing the
DISPLAY button. The buzzer will be silenced but the LEDs will continue to
flash. If you return to Measuring Mode and there is still an alarm condition,
the LEDs will continue to flash and the buzzer will remain off. Once the
condition clears, press POWER ENTER RESET to clear the alarm
indications.
With ALARM SILENCE set to OFF, you cannot silence the buzzer. If an
alarm condition occurs, and you enter Display Mode, the buzzer will not be
silenced and the LEDs will continue to flash. Upon return to Measuring
Mode, if there is still an alarm condition, you must wait until it clears before
you can press POWER ENTER RESET to clear the alarm indications.
1. From the main menu, place the cursor next to ALARM SILENCE.
2. Press and release POWER ENTER RESET. The Alarm Silence Option
Screen appears.
ALARM LATCHING
UP/DOWN THEN ENTER
LATCHING
ALARM
SILENCE OPTION
UP/DOWN THEN ENTER
ON