Testing the program, Graphics only, Dry run with table movement – ACU-RITE MILLPWRG2 User Manual
Page 142: Graphics only dry run with table movement, 1 demonstr ation pr ogr am
124
7 Demonstration Program
7.
1 Demonstr
ation Pr
ogr
am
Testing the Program
Whenever a new program has been created, it should always be
tested first.
Graphics only
The following steps will run the program graphically only, and there
will be no table movement.
Press the Run Options soft key.
Press the Graphics Only soft key.
Use the arrow up key to highlight step 001 of the
program.
Press the Exit soft key.
Press the GO soft key (there will be no table
movement). The part machining steps will be shown
in the display graphics.
Dry Run with table movement
The complete program will be run, and the cutting of the part will be
displayed graphically as the program steps are being performed.
The following steps will run the program graphically, and the table will
move.
Before you press the GO key to begin the dry run, ensure
that the tool will not touch the workpiece when the quill
begins to move. To avoid tool interference, do one or more
of the following:
- Lower the knee
- Remove the tool or workpiece
- Reestablish datum away from the part