2 f o lders – ACU-RITE MILLPWRG2 User Manual
Page 118

100
6 Programming
6.2 F
o
lders
G-code
Description
Comment
G28
Return to Home Reference
MILLPWR
G2
does not have a method for establishing a "home" position.
If one or more coordinates are specified in the block, the table/quill will
rapid to that location. Program execution will continue with the next
program block.
G30
G40
†
Cancel Cutter Compensation
MILLPWR
G2
supports automatic cutter compensation. Enable cutter
compensation using G41 (left) or G42 (right). Disable compensation
using G40 (center).
G41
†
Cutter Compensation (Left)
G42
†
Cutter Compensation (Right)
G43
Tool Length Offset (+)
MILLPWR
G2
does not support tool length offsetting. The offset is
retrieved from MILLPWR
G2
’s tool library when a tool change is
executed. These commands are ignored.
G44
Tool Length Offset (-)
G49
Cancel Tool Length
G54
Work Coordinate System
MILLPWR
G2
does not support presettable work coordinate systems.
G54 through G59 are ignored. Selecting a coordinate system is possible,
but setting it (G10 or G92) will generate a run-time error
G55
G56
G57
G58
G59