Calibration table Info Data tab
This tab includes the following:
●
Output Density
Measured
The values that are measured from the printed target.
Target
The maximum accepted values of the output density.
Notes:
○
The target values are set higher than the expected values of
the output density. Measured values do not need to match the
target values. Measured values will be lower than the target
values .
○
For the target value, the measured value is displayed instead
of the real target value if the calibration look-up table is
generated by off-the-glass-calibration.
○
For the target curve, the virtual target curve is displayed
instead of the real target curve if the calibration look-up table
is generated by off-the-glass-calibration.
Minimum Accepted
The minimum measured value of the output density that
is accepted for correction.
●
Properties—The parameters that were selected when the
calibration table was created.
Calibration table Info Data tab