Section 6. Data Table Declarations and Output Processing Instructions

Parameter
& Data Type

Enter

CARDOUT PARAMETERS

StopRing

Constant

A code to specify if the Data Table on the PCMCIA card is fill and stop or ring (newest
data overwrites oldest).

Value Result

0 Ring

1

Fill and Stop

Size

Constant

The size to make the data table. The number of data sets (records) to allocate memory for
in the PCMCIA card. Each time a variable or interval trigger occurs, a line (or row) of
data is output with the number of values determined by the output Instructions within the
table. This data is called a record.
Note:
Enter a negative number and all remaining memory (after creating fixed size data
tables) will be allocated to the table or partitioned between all tables with a negative value
for size. The partitioning algorithm attempts to have the tables fill at the same time. Enter
-1000 to set the size of the table on the card to the size of the table in the datalogger's
memory.

DSP4 (FlagVar, Rate)

This instruction is used to send data to the DSP4. If this instruction appears
inside a DataTable declaration, the DSP4 can display the fields of that
DataTable. To view the Public DataTable (variables declared with the Public
instruction), place the DSP4 instruction in the Declaration program area, but
not inside of a DataTable construct.

The Instruction can only be used once in a program; hence, only
the public variables or a single Data Table can be viewed.

NOTE

Parameter
& Data Type

Enter

DSP4 PARAMETERS

FlagVar

Array

The variable array to use for the 8 flags that can be displayed and toggled by the DSP4. A value of 0 =
low;

≠0 = high. If the array is dimensioned to less than 8, the DSP4 will only work with the flags up to

the declared dimension. The array used for flags in the Real Time displays of RTDAQ is Flag (8).

Rate

Constant

How frequently to send new values to the DSP4 in milliseconds.

Example

DataTable( MAIN, 1, 2222 ) 'Trigger set, 2222 Records
DataInterval( 0, TBLINT1, UNITS1, 100 ) '200 mSec, 100 lapses
Maximum( Reps, Tblk1(), FP2, 0, 0 )

'Reps,Source,Res,Disable,Time of Max/Min

Minimum( Reps, Tblk1(), FP2, 0, 0 )

'Reps,Source,Res,Disable,Time of Max/Min

Average( Reps, Tblk1(), FP2, 0 )

'Reps,Source,Res,Disable

DSP4

( Flag, 200 )

'DSP4 displays MAIN, updates every 200 mS

EndTable

'End of table MAIN