Campbell Scientific CR1000 Measurement and Control System User Manual
Page 543

Appendix B. Status Table and Settings
543
Table 122. CR1000 Settings
Settings are accessed through the Campbell Scientific Device Configuration Utility (DevConfig) via direct-serial and IP connections, or through
PakBusGraph via most CR1000 supported telecommunications options.
Setting Description
Default
Entry
Routes
This read-only setting lists the routes, in the case of a router, or the router neighbors, in
the case of a leaf node, that were known to the CR1000 at the time the setting was read.
Each route is represented by four components separated by commas and enclosed in
parentheses:
(port, via neighbor adr, pakbus adr, response time)
Descriptions of components:
Port
Specifies a numeric code for the port the router will use:
Port
Numeric
Description
Code
ComRS232
1
ComME
2
ComSDC6 (Com310)
3
ComSDC7
4
ComSDC8
5
ComSDC9 (Com320)
6
ComSDC10
7
ComSDC11
8
Com1
9
Com2
10
COM3
11
COM1, COM2, COM3, or
COM4
12
IP*
101,102,…
*If the value of the port number is ≥ 101, the connection is made through PakBus/TCP,
either by the CR1000 executing a TCPOpen() instruction or by having a connection
made to the PakBus/TCP logger service.
Via Neighbor Address
Specifies address of neighbor/router to be used to send messages for this route. If the
route is for a neighbor, this value is the same as the address.
PakBus® Address
For a router, specifies the address the route reaches. If a leaf node, this is 0.
Response Time
For a router, specifies amount of time (in ms) that is allowed for the route. If a leaf node,
this is 0.
(1, 4089, 4089,
1000)
USR: Drive Size
Specifies the size in bytes allocated for the "USR:" ram disk drive.
0