beautypg.com

Campbell Scientific CR1000 Measurement and Control System User Manual

Page 337

background image

Section 8. Operation

337

 

Example: 

"TOB1","11467","CR1000","11467","CR1000.Std.20","CPU:file format.CR1","61449","Test"
"SECONDS","NANOSECONDS","RECORD","battfivoltfiMin","PTemp"
"SECONDS","NANOSECONDS","RN","",""
"","","","Min","Smp"
"ULONG","ULONG","ULONG","FP2","FP2"
}Ÿp' E1HŒŸp' E1H›Ÿp' E1HªŸp' E1H¹Ÿp'

E1H

TOA5

TOA5 files contain ASCII

 (p. 447

header and comma‐separated data. 

Example: 

"TOA5","11467","CR1000","11467","CR1000.Std.20","CPU:file format.CR1","26243","Test"
"TIMESTAMP","RECORD","battfivoltfiMin","PTemp"
"TS","RN","",""
"","","Min","Smp"
"2010-12-20 11:31:30",7,13.29,20.77
"2010-12-20 11:31:45",8,13.26,20.77
"2010-12-20 11:32:00",9,13.29,20.8

CSIXML

CSIXML files contain header information and data in an XML

 (p. 471) 

format. 

Example: 



11467
Test
CR1000
11467
CR1000.Std.20
CPU:file format.CR1



13.2921.04
13.2921.04
13.2921.04

CSIJSON

CSIJSON files contain header information and data in a JSON

 

format.