Campbell Scientific CR1000 Measurement and Control System User Manual
Page 533

Appendix B. Status Table and Settings
533
Table 121. Status-Table Fields and Descriptions
Fieldname Description
Variable
Type
Default
Range
Edit?
Info
Type
MeasureTime
Time (μs) required to make
the measurements in this
scan, including integration
and settling times. Processing
occurs concurrent with this
time so the sum of measure
time and process time is not
the time required in the scan
instruction. This is a static
value calculated at compile
time. Assumes all
measurement instructions
will run each scan.
Integer
Status
ProcessTime
Processing time (μs) of the
last scan. Time is measured
from the end of the EndScan
instruction (after the
measurement event is set) to
the beginning of the EndScan
(before the wait for the
measurement event begins)
for the subsequent scan.
Calculated dynamically (on
the fly).
Integer
Status
MaxProcTime
Maximum time (μs) required
to run through processing for
the current scan. This value
is reset when the scan exits.
Calculated dynamically (on
the fly).
Integer
Yes
Reset by
changing to 0
Status
BuffDepth
Shows the current Pipeline
Mode processing buffer
depth., which indicates how
far processing is currently
behind measurement.
MaxBuffDepth
Gives the maximum number
of buffers processing lagged
measurement.
LastSystemScan8
The last time the background
calibration executed.
Integer array
Status
LastSlowScan9
The last time SlowSequence
scan(s) executed.
Integer array
Status
SystemProcTime8,12
The time (μs) required to
process the background
calibration.
Integer array
Status
SlowProcTime9,12
The time (μs) required to
process SlowSequence
scan(s).
Integer array
Status
MaxSystemProcTime8,
13
The maximum time (μs)
required to process the
background calibration.
Integer array
Status