Crbasic example 38. custom menus – Campbell Scientific CR1000 Measurement and Control System User Manual
Page 196

Section 7. Installation
196
Figure 67: Custom menu example — control-LED pick list
Figure 68: Custom menu example — control-LED Boolean pick list
Note See figures Custom Menu Example — Home Screen
(p. 194)
through Custom
Menu Example — Control LED Boolean Pick List
(p. 196)
in reference to the
following CRBasic example Custom Menus
(p. 196).
CRBasic Example 38. Custom Menus
'Custom Menu Example
'Declarations supporting View Data menu item
Public
RefTemp
'Reference Temp Variable
Public
TCTemp(2)
'Thermocouple Temp Array
'Delarations supporting blank line menu item
Const
Escape = "Hit Esc"
'Word indicates action to exit dead end
'Declarations supporting Enter Notes menu item
Public
SelectNote
As String
* 20
'Hold predefined pick list note
Const
Cal_Done = "Cal Done"
'Word stored when Cal_Don selected
Const
Offst_Chgd = "Offset Changed"
'Word stored when Offst_Chgd selected
Const
Blank = ""
'Word stored when blank selected
Public
EnterNote
As String
* 30
'Variable to hold free entry note
Public
CycleNotes
As String
* 20
'Variable to hold notes control word
Const
Accept = "Accept"
'Notes control word
Const
Clear = "Clear"
'Notes control word
'Declarations supporting Control menu item
Const
On = true
'Assign "On" as Boolean True