A.2.3 final data storage (output) processing, A.2.3.1 single-source – Campbell Scientific CR1000 Measurement and Control System User Manual
Page 477

Appendix A. CRBasic Programming Instructions
477
TableFile
Writes a file from a data table to a CR1000 memory drive.
Syntax
TableFile("FileName", Options, MaxFiles, NumRecs /
TimeIntoInterval, Interval, Units, OutStat, LastFileName)
A.2.3 Final Data Storage (Output) Processing
Read More! See Data Output Processing Instructions
(p. 131).
FieldNames
Immediately follows an output processing instruction to change default field
names.
Syntax
FieldNames("Fieldname1 : Description1, Fieldname2 :
Description2…")
A.2.3.1 Single-Source
Average
Stores the average value over the output interval for the source variable or each
element of the array specified.
Syntax
Average(Reps, Source, DataType, DisableVar)
Covariance
Calculates the covariance of values in an array over time.
Syntax
Covariance(NumVals, Source, DataType, DisableVar, NumCov)
FFT
Performs a Fast Fourier Transform on a time series of measurements stored in an
array.
Syntax
FFT(Source, DataType, N, Tau, Units, Option)
Maximum
Stores the maximum value over the output interval.
Syntax
Maximum(Reps, Source, DataType, DisableVar, Time)
Median
Stores the median of a dependant variable over the output interval.
Syntax
Median(Reps, Source, MaxN, DataType, DisableVar)
Minimum
Stores the minimum value over the output interval.
Syntax
Minimum(Reps, Source, DataType, DisableVar, Time)