Pfadvantage, Mid-tech controller, Ag leader technology – Ag Leader PFadvantage Harvest & Application Operators Manual User Manual
Page 62: Application rate mode

Mid-Tech Controller
PFadvantage
Application Rate Mode
Ag Leader Technology
September 2003
2-50
Setup for Mid-
Tech controllers
that are
connected to
Data-Link
consoles
Complete the following steps to set up for Ag Logic, TASC 6000,
6100, 6200, 6300, 6500, 6600 with Data Link.
A separate configuration of settings should be created for every
product applied. A maximum of 16 different configurations can be
created. The screen below illustrates two configurations set up for a
Mid-Tech.
1. Press SETUP key. Press APP RATE CONFIG key. A screen
similar to the one below should appear.
APP RATE CONFIG
PRODUCT CONTROLLER CHANNEL
Treflan TASC
6100 Carrier
Roundup TASC
6100
Carrier
EDIT
SETTINGS
CREATE
NEW
DELETE
EXIT
Press CREATE NEW key to set up a new configuration or select
an existing configuration and press the EDIT SETTINGS key. A
new screen appears with the following settings. Select each
setting and press EDIT key to change the settings.
Controller Make: Set to MIDTECH. This setting can not be
changed once the configuration is used by one or more fields.
Controller Model: Set to the MIDTECH model you have. For
example: TASC 6100 etc. This setting can not be changed once
the configuration is used by one or more fields.
Product: Press EDIT key. You can select an existing product
and press ACCEPT key or create a new product by pressing
CREATE NEW key. Press EDIT NAME key and enter name of
product. Use Left or Right Arrow keys to select a character. Use
Up or Down Arrow key to change the character. To erase a
character in the name, highlight that character and use UP or
DOWN ARROW key to scroll to the blank space between "9"
and "A". Set every character and press ACCEPT key twice.