Vehicle Setup

PFadvantage

Harvest Mode

Ag Leader Technology

September 2003

2-32

Area count stop
beeps

This setting is for the number of times the monitor beeps when the head is
raised at the end of a pass and the monitor stops counting area.

NOTE: The recommended setting is 20. Set this number high enough so
that after the head is raised at the end of a pass, the beeps continue until the
combine is completely turned around and the head is lowered to start the
new pass. This gives the operator an audible signal that the head is
lowered enough to begin counting area again.


Expand grain below

If you select . . .

Then . . .

Dry %

No,

You prevent the monitor from adding bushels to grain
that is dryer than the dry percent moisture by which dry
bushels are calculated. This calculates all yields in terms
of actual bushels available for you to sell.
(Recommended setting).

Yes,

The monitor shows a yield comparison of all loads at
the dry percent moisture. This increases the bushels of
the grain harvested below the dry percent moisture to
account for moisture lost because of excessive dryness
of the grain.

NOTE: This setting applies to all loads and grains in the monitor. It can be
changed from NO to YES and vice-versa at any time.

Sensor calibration

Refer to the Initial Calibration Sheet for the correct setting for your
combine.

NOTE: If you replace the flow sensor, you must change this setting to the
value of the new sensor calibration number for the new flow sensor. The
sensor calibration number is listed on the flow sensor serial number tag.

T1, T2, T3

Refer to the Initial Calibration Sheet for the correct setting for your
combine.