Configuration File Loader 114


5-3-3 Port Settings

The [Port] tag allows you to set the port information and the change the security switch (Secure Manager XP) to

ON or OFF. You can change the [Port] tag definitions, but may not add or delete them.
You cannot change the NAS settings using the spreadsheet. However, the current NAS settings are commented

on the exported spreadsheet (the rows start with “#$”).

Do not change the NAS comment rows.

Table 5-5 lists the items and values available for the [Port] tag.

Table 5-5

Available [Port] Tag Configuration Values

Column

Item

Available Values

1st , 11th (Index) Port

Set one of the following (Maximum number of ports is 256):
1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1Q, 1R,
2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N, 2P, 2Q, 2R,
3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H, 3J, 3K, 3L, 3M, 3N, 3P, 3Q, 3R,
4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4J, 4K, 4L, 4M, 4N, 4P, 4Q, 4R,
5A, 5B, 5C, 5D, 5E, 5F, 5G, 5H, 5J, 5K, 5L, 5M, 5N, 5P, 5Q, 5R,
6A, 6B, 6C, 6D, 6E, 6F, 6G, 6H, 6J, 6K, 6L, 6M, 6N, 6P, 6Q, 6R,
7A, 7B, 7C, 7D, 7E, 7F, 7G, 7H, 7J, 7K, 7L, 7M, 7N, 7P, 7Q, 7R,
8A, 8B, 8C, 8D, 8E, 8F, 8G, 8H, 8J, 8K, 8L, 8M, 8N, 8P, 8Q, 8R,
9A, 9B, 9C, 9D, 9E, 9F, 9G, 9H, 9J, 9K, 9L, 9M, 9N, 9P, 9Q, 9R,
AA, AB, AC, AD, AE, AF, AG, AH, AJ, AK, AL, AM, AN, AP, AQ, AR,
BA, BB, BC, BD, BE, BF, BG, BH, BJ, BK, BL, BM, BN, BP, BQ, BR,
CA, CB, CC, CD, CE, CF, CG, CH, CJ, CK, CL, CM, CN, CP, CQ, CR,
DA, DB, DC, DD, DE, DF, DG, DH, DJ, DK, DL, DM, DN, DP, DQ, DR,
EA, EB, EC, ED, EE, EF, EG, EH, EJ, EK, EL, EM, EN, EP, EQ, ER,
FA, FB, FC, FD, FE, FF, FG, FH, FJ, FK, FL, FM, FN, FP, FQ, FR,
GA, GB, GC, GD, GE, GF, GG, GH, GJ, GK, GL, GM, GN, GP, GQ, GR

2nd, 12th

Security Switch (Secure
Manager XP)

Enable or Disable (The default when the spreadsheet is exported)
ON or OFF are also available as the set value when you write the spreadsheet.

3rd, 13th

AL-PA

Set with hexadecimal numbers in one or two digits.

4th, 14th

Fabric

Enable or Disable (The default when the spreadsheet is exported)
ON or OFF are also available as the set value when you write the spreadsheet.

5th, 15th

Connection

FC-AL or P to P

6th, 16th

Channel Speed

Set one of the following:
1, 2, or Auto