Confirm window, Added luns table – HP XP P9500 Storage User Manual
Page 349

Description
Item
•
Nondisruptive Migration: Volume for the nondisruptive migration.
•
-: Volume in which the attribute is not defined.
Number of assigned LUNs.
LUN ID ((number of LUNs) Sets of
Paths)
Name of the port and the host group of assigned LUNs. This item appears
according to the number of assigned LUNs.
port ID
/ host group name
To change the LDEV name setting, select an LDEV and then click this button.
Change LDEV Settings
To change the LUN setting, select the check box in the table column of port
ID
/host group name, select the target LDEV, and then click this button.
Change LUN IDs
Confirm window
Confirm proposed settings, name the task, and then click Apply. The task will be added to the
execution queue.
Added LUNs table
Description
Item
Identifier of the LDEV.
LDEV ID
Name of the LDEV.
LDEV Name
Identifier of the parity group.
Parity Group ID
Pool names and pool identifiers.
Pool Name (ID)
If the LDEV is not used as a pool-VOL, a hyphen (-) appears.
Emulation types for each logical volume (or logical device). For LUSE
volumes, an asterisk (*) and a number appear on the right of the emulation
Emulation Type
type. For example, OPEN-9*3 indicates that three OPEN-9 volumes are
combined.
Size of each logical volume.
Capacity
Provisioning types for each logical volume.
Provisioning Type
Add LUN Paths wizard 349