HP XP P9500 Storage User Manual
Page 194

Solutions
Error Contents
Error Code (SSB2)
Increase the THP V-VOL capacity after the
specified volume is placed online with the OS
which supports EAV.
The operation was rejected because the
specified volume is placed online with the OS
which does not support EAV (Extended Address
Volume).
0xaf22
Specify a capacity so that the pool reservation
rate will not be exceeded.
The operation was rejected because the total
THP V-VOL capacity exceeded the pool
0xaf24
reservation rate after the capacity was
increased.
Specify a capacity so that the maximum number
of cache management devices will not be
exceeded.
The operation was rejected because of lack of
cache management devices due to increased
capacity.
0xaf26
Makes sure that the volume is a THP V-VOL.
Because the specified volume was not a THP
V-VOL, the operation was rejected.
0xaf29
To increase capacity, specify the correct
capacity that does not exceed the value
Because the specified capacities are invalid or
exceeded the value immediately below LDEV
0xaf2a
immediately below LDEV Capacity in the Expand
Capacity in the Expand Virtual Volumes
window, the operation was rejected.
Virtual Volumes window. See the conditions for
increasing THP V-VOL capacity in
Re-execute the operation after a brief interval.
Because the specified volume operation was not
finished, the operation was rejected.
0xaf2b
Confirm the value immediately below LDEV
Capacity in the Expand Virtual Volumes
window.
Because the shared memory capacity is not
enough to increase the specified capacity, the
operation was rejected.
0xaf2c
Wait until formatting of the specified volume is
finished, or see
and confirm whether
Because the specified THP V-VOL was used by
other software or was being formatted, the
operation was rejected.
0xaf2e
the THP V-VOL is used with software in which
that the THP V-VOL capacity cannot be
increased.
Re-execute the operation after the microcode is
replaced.
Because the THP V-VOL capacity was increased
when the microcode was replaced, the
operation was rejected.
0xaf2f
Re-execute the raidcom extend ldev
command without specifying the -cylinder
option.
Because the raidcom extend ldev
command was executed with specifying the
-cylinder
option to the THP V-VOL for the
open system, the operation was rejected.
0x0b2b
Errors when operating RAID Manager (Data Retention, SSB1:B9BF/B9BD)
Description
Error Code (SSB2)
The setting failed because the specified volume does not exist.
B9BD
The specified volume is a command device.
B9C2
The command was rejected due to one of the following reasons:
B9C4
•
The specified volume is a P-VOL or S-VOL of Snapshot.
•
The specified volume is a virtual volume.
•
The specified volume is a pool volume.
•
The specified volume is an S-VOL of Continuous Access Journal.
•
The specified volume is a journal volume.
•
The specified volume is reserved for the Auto LUN function.
•
The specified volume is a P-VOL or S-VOL of Business Copy.
•
The consumed capacity exceeded the licensed capacity.
194
Troubleshooting