4 Managing the network
Correctly setting up the network for HP StoreVirtual Storage ensures data availability and reliability.
IMPORTANT:
The network settings must be the same for the switches, clients, and storage systems.
Set up the end-to-end network before creating storage volumes.
Network best practices
•
Isolate the SAN, including CMC traffic, on a separate network. If the SAN must run on a
public network, use a VPN to secure data and CMC traffic.
•
Configure all the network characteristics on a storage system before creating a management
group, or before adding the storage system to a management group and cluster.
•
Use static IP addresses, or reserved addresses if using DHCP.
•
Have flow control enabled.
•
Configure storage system settings for speed and duplex, frame size, and flow control BEFORE
bonding NICs and before putting the storage system into a management group and cluster.
IMPORTANT:
◦
NIC bonding between the two virtual NICs in the HP StoreVirtual VSA for VMware vSphere
is not supported. (The HP StoreVirtual VSA for Microsoft Hyper-V only supports a single
NIC.)
◦
You cannot change the speed, duplex, or flow control of a StoreVirtual VSA.
•
If adding a second IP address to a storage system, the second IP address must be on a separate
subnet. If the two IP addresses are on the same subnet, they must be bonded.
Split network configurations
Implement a split network configuration to use the CMC on a management network separate from
the storage network. HP recommends that you only configure a management network when the
storage systems are equipped with a sufficient number of network adapters so that the storage
systems can support both bonded NICs for optimal redundancy and performance on the storage
network, along with a separate management interface. Keep in mind the following requirements
when considering the creation of a management network.
•
Configure a management network only if your storage systems have more than two NICs.
Two NICs are the minimum number required to create a bonded interface for the storage
network to provide maximum redundancy and performance.
•
Use only available HP StoreVirtual upgrade kits to alter the hardware configuration of an HP
StoreVirtual Storage system. Alterations using any other hardware are not supported.
•
Be aware that the CMC can manage storage systems via a routed network or by installation
of a second NIC on the storage network on the CMC host. This is the most common method
for CMC management.
•
When configuring a management interface on an HP StoreVirtual Storage system, make sure
that interface is on a separate network. Also make sure there is not a route between the
management and data networks. Configuring two separate interfaces on the same IP network
is not supported and will result in communication problems in the cluster.
•
When configuring a management interface on an HP StoreVirtual Storage system, be aware
that only one interface can be configured with a default gateway, and that interface should