Installing the raid controller – HP LeftHand P4000 SAN Solutions User Manual
Page 261
Figure 132 Removing the cache module
9.
Remove the RAID controller from its slot.
Installing the RAID controller
IMPORTANT:
The replacement RAID controller contains a new cache module. You must remove
the cache module on the replacement controller board and attach the existing cache module to
the replacement controller board and reconnect the cache module to the battery cable.
1.
Slide the RAID controller into the slot, aligning the controller with its matching connector. See
if you are replacing Card 1 and
if you are
replacing Card 2. Firmly press the controller to seat it properly on the slot.
2.
Tighten the screws to secure the RAID controller to the PCI cage (3,
and
).
Figure 133 Installing Card 1
Replacing the RAID controller
261