Orion classic endpoint ir – Badger Meter ORION Classic (CE) User Manual
Page 34

ORION Classic Endpoint IR
Use the ORION IR Programming function to read ORION Classic
water and gas endpoints, and to start, stop and pause an
endpoint
The
ORION IR Programming function
is also used to
program
an endpoint following a tamper repair or retrofit
installation (RTR water installations only)
Figure 47: IR Programming screen for ORION classic endpoint
NOTE:
N
Prior to performing any of the ORION Classic endpoint IR functions, connect the IR programming cable and an
ORION Classic mobile receiver (if necessary) to the handheld, and make sure the appropriate COM ports are set See
if you need help
ORION Classic Endpoint IR Buttons
Read
Read the endpoint using the IR programming cable
Program /
Force Read
When used with an RTR encoder, Program is used to set the endpoint odometer value following a tamper
repair When used with an ADE encoder, Force Read is used to view the real-time encoder odometer value
Stop
Stop the endpoint from sending a transmission Stopped endpoints must be re-programmed to begin
transmitting again
Pause
Pause the endpoint transmission temporarily until a unit of water or gas is registered (Common practice of
seasonal users )
Start
Start the endpoint radio transmission
HPwr
Force a brief high powered signal from the endpoint to an ORION Classic gateway receiver
Listen
Switches to RF (radio frequency) to "hear" if the endpoint is active
ORION Classic Endpoint IR Buttons - Gas Endpoint Only
Drive Circle? Displays after initial read for ORION Classic gas endpoints only Provides access to a read-only screen
displaying the possible drive circles for the gas endpoint
Change DC
Displays after initial read for gas endpoints only Used to select the gas drive circle information
ORION Classic Endpoint IR Fields
Serial #
Displays the serial number of the ORION CE endpoint
Reading
Used to view the current endpoint reading value For an RTR, it is used in conjunction with the Program
button to reprogram the odometer value after a tamper repair
Status
Displays the endpoint status which provides information regarding the programming and configuration of
the endpoint See
for a list of status codes.
Radio
Used to view the endpoint radio transmission mode
ORION IR PROgRAMMINg
Page 34
April 2014
ORION® Endpoint Utility for Trimble® Ranger 3