Ir programming an orion migratable endpoint (rtr) – Badger Meter ORION Classic (CE) User Manual
Page 20

IR Programming an ORION Migratable Endpoint (RTR)
When used with an RTR encoder, you must program and set the endpoint odometer value following a tamper repair
Reading the Odometer
To install an ORION Migratable endpoint on an active meter with usage on the RTR, use the following information to ensure
that the value in the endpoint matches the current odometer value on the RTR once the endpoint is connected to the RTR
When programming ORION endpoints, enter the value of the
six moveable odometer wheels plus the sweep hand for all
meter types (gallons, cubic feet, etc ) and all meter models
In Figure 19, the odometer value in the moveable dials (both
white and black digits) is "000001 "
The sweep hand is pointing between the "6" and the “7" but
because the sweep hand has not yet hit the "7", use "6" as the
value for the last digit of the meter reading Therefore, in this
example, the value to be entered into the ORION endpoint
Reading field would be "16" or "0000016 " (The leading zeros
are not required )
Figure 19: Odometer value
When programming an ORION endpoint connected to an
E-Series meter with an RTR protocol, program the seven most
significant (left-most) digits shown on the meter display
NOTE:
N
For instructions on programming a gas endpoint,
see
"IR Programming an ORION Migratable gas
Figure 20: E-Series meter display
1 Align the optical head of the IR cable with the
endpoint IR LED port and tap Read on the IR
Programming screen
2 Double-tap the reading in the Reading field
Result: The current reading in the field is highlighted
(Figure 21).
Figure 21: RTR Reading field