Badger Meter Remote Electronic Display (RED) User Manual

Installation data, Recordall® transmitter register (rtr®), Remote electronic display (red)

background image

Recordall® Transmitter Register (RTR®)

Remote Electronic Display (RED)

Installation Data

RED-I-01 (10-10)

64573-002 Rev. 4

SUGGESTED TOOLS

• Electric

Drill

• 3/16” Carbide Tip Masonry Drills

• Screw

Driver

• Wire

Stripper

• T-10 Stapler with Cable Attachment

• 59983-001

Crimping

Tool

• 59989-001 Cable Stripper

• 59991-001 Wire Cutting Pliers

MISCELLANEOUS PARTS PROVIDED

• Two

Wire

Connectors

• Seal

Screw

• Strain Relief Ring

• Units of Measure Label

REQUIRED MATERIAL

• Non-Corrosive

Staples

• Caulking

Compound

• Masonry

Fasteners

• Non-Corrosive

Screws

• 62440-001 Belden 8451 Wire if proper length not supplied with

RTR®

IDENTIFICATION

The Model RED (Remote Electronic Display) remote reading

registers are designed for use with all Badger® Recordall® Disc,

Turbo, Compound and Fire Series meters equipped with RTR®

registers, plus the Badger Magnetoflow® meter.

REGISTER INSTALLATION

While the RED electronics and battery are environmentally

sealed and suitable for outdoor installation, the wire terminals

are not sealed from moisture. The unit, therefore, should not

be installed in locations below grade level or in a submersible

environment.

1. Remove register cover.

2. Using the register base as a template, locate and mark

mounting holes on outside wall of building. For best results

the RED should be located at eye level in an easily accessible

location.

3. Secure register base to wall using the mounting dimensions

in the drawing below to drill the locating holes.

NOTE: Avoid mounting register on loose siding of any type

since this will only lead to wire breakage or other potential

problems. (Register mounting hardware is supplied by the

customer).

4. Drill a 3/16” wire entry hole at a suitable location in the build-

ing wall.

5. Run the wire from the meter-mounted RTR through the hole

in the wall to the Remote Electronic Display register.

6. Cut the wire to proper length at the register, allowing suffi-

cient wire for connection to the register. Maximum wire length

between the RTR and the RED register is 3000 feet using Belden

8451 wire.

NOTE: Wire access to the Remote Electronic Display register is

through a bottom access port. Allow sufficient wire to form a

small U-shaped loop where the wire enters the building. The

loop eliminates the possibility of rainwater running down the

wire into the building.