Alarm menu – Watlow EZ-ZONE RM Limit Module Rev C User Manual
Page 52
![background image](/manuals/359088/52/background.png)
Watlow EZ-ZONE
®
RML Module
•
49
•
Chapter 4 Setup Page
RM Limit Module
•
Setup Page
Display
Parameter Name
Description
Range
Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Parameter
ID
Data
Type
&
Read/
Write
[`o;Lo]
[ o.Lo]
Output (1 to 4 and 7 - 10)
Low Power Scale
The power output will nev-
er be less than the value
specified and will represent
the value at which output
scaling begins.
0.0 to 100.0%
0.0%
1866
[offset 30]
0x6A
(106)
1 to 10
9
- - - -
6009
float
RWES
[`o;hi]
[ o.hi]
Output (1 to 4 and 7 - 10)
High Power Scale
The power output will
never be greater than the
value specified and will
represent the value at
which output scaling stops.
0.0 to 100.0%
100.0%
1868
[offset 30]
0x6A
(106)
1 to 10
0xA (10)
- - - -
6010
float
RWES
[Alm]
[`Set]
Alarm Menu
[`A;ty]
[ A.ty]
Alarm (1 to 16)
Type
Select whether the alarm
trigger is a fixed value or
will track the set point.
[`oFF]
Off (62)
[PR;AL]
Process Alarm (76)
Off
2558
[offset 60]
0x6D
(109)
1 to 16
0xF (15)
20
9015
uint
RWES
[`Sr;A]
[ Sr.A]
Alarm (1 to 16)
Source Function A
Select what will trigger
this alarm.
[none]
None (61)
[``Ai]
Analog Input (142)
[CUrr]
Current (22)
[PWr]
Power, Control Loop
(73)
[`lnr]
Linearization (238)
[mat]
Math (240)
[``Pu]
Process Value (241)
[`uAr]
Variable (245)
[`CU;r]
Current Read (179)
2562
[offset 60]
0x6D
(109)
1 to 4
0x11 (17)
21
9017
uint
RWES
[`is;A]
[ iS.A]
Alarm (1 to 16)
Source Instance A
Set the instance of the
function selected above.
1 or 250
1
2564
[offset 60]
0x6D
(109)
1 to 16
0x12 (18)
22
9018
uint
RWES
[`S2;A]
[ SZ.A]
Alarm (1 to 16)
Source Zone A
Set the zone of the function
selected above.
0 or 16
0
2578
[offset 60]
0x6D
(109)
1 to 16
0x19 (25)
- - - -
9025
uint
RWES
[`A;hy]
[ A.hy]
Alarm (1 to 16)
Hysteresis
Set the hysteresis for an
alarm. This determines
how far into the safe region
the process value needs to
move before the alarm can
be cleared.
0.001 to 9,999.000°F or units
0.001 to 5,555.000°C
1.0°F or
units
1.0°C
2534
[offset 60]
0x6D
(109)
1 to 16
3
24
9003
float
RWES
[`A;Lg]
[ A.Lg]
Alarm (1 to 16)
Logic
Select what the output
condition will be during the
alarm state.
[`AL;C]
Close On Alarm (17)
[`AL;o]
Open On Alarm (66)
Close On
Alarm
2538
[offset 60]
0x6D
(109)
1 to 0x10
(16)
5
25
9005
uint
RWES
Note: Some values will be rounded off to fit in the four-character display .
Full values can be read with other interfaces .
If there is only one instance of a menu, no submenus will appear .
R: Read
W: Write
E:
EEPROM
S:
User
Set