IAI America RCM-GW-PR User Manual
Page 74

68
PfofiBus Gateway
Command name
Byte+*1
PLC output (request)
PLC input (response)
Deceleration write
+4
1006H
Same as the value in the
request command if normal.
6 Position
number
8 Deceleration
data
*5
10 0
12
Axis number 0 to FH *3
14 (RSV)
16 (RSV)
Push motion current-
limiting value write
+4
1007H
Same as the value in the
request command if normal.
6 Position
number
8
0000 to 00FFH
(00FFH: maximum current)
10 0
12
Axis number 0 to FH *3
14 (RSV)
16 (RSV)
Load current threshold
write
+4
1008H
Same as the value in the
request command if normal.
6 Position
number
8
0000 to 00FFH
(00FFH: maximum current)
10 0
12
Axis number 0 to FH *3
14 (RSV)
16 (RSV)
*1 Relative byte address recognized with respect to the Gateway head address
*2 Signed 32-bit integer data
*3 Data 00 to 0FH correspond to axis numbers (0) to (15), respectively.
*4 32-bit integer data
*5 Eight-bit
integer
data
*6 This command is effective only with those position table numbers for which a push-current
limiting value (push-motion operation setting) other than 0 has been set.