PfofiBus Gateway

I/O Signal Details

Signal type

Bit

Signal

name

Description Details

PL

C

ou

tput

Control

signal

b7 -

Cannot

be

used.

-

b6 -

Cannot

be

used.

-

b5 -

Cannot

be

used.

-

b4

SON

Servo on command

6.2 (7)

b3 STP

Pause

command

6.2

(5)

b2

HOME

Home return command

6.2 (8)

b1 CSTR

Start

command

6.2

(9)

b0

RES

Reset command

6.2 (4)

Command

position

number

6-bit
data

(b5-0)

RC 32

~

PC1

Specify the command position number using a
binary value.*1

6.2 (11)

PLC inp

u

t

Status

signal

b7

EMGS

Emergency stop

6.2 (2)

b6 -

Cannot

be

used.

-

b5 PWR

Controller

ready

6.2

(1)

b4

SV

Ready (servo is on)

6.2 (7)

b3 MOVE

Moving

6.2

(6)

b2

HEND

Home return complete

6.2 (8)

b1 PEND

Positioning

complete

6.2

(10)

b0 ALM

Alarm

6.2

(3)

Zone signal

output 2

b7

ZONE2

*2

The completed position number and zone signal
status are output. Read the completed position
number as a six-bit binary value.
While an alarm is present (= the ALM signal is ON),
the content of the alarm is output to the completed
position number.
(For the contents of alarms that may be output,
refer to the table entitled “Alarm List” on the next
page.)

6.2 (13)

Zone signal

output 1

b6 ZONE1

Completed

position

number

(alarm

output)

6-bit
data

(b5-0)

PM32

~

PM1

6.2 (12)


*1 With the ERC2-NP/PN, up to 16 positioning points are supported in PIO control. If the gateway unit is

connected, however, up to 64 points can be specified.

*2 [ZONE2] is not supported by the ERC2-NP/PN.