IAI America RCM-GW-PR User Manual
Page 47
41
PfofiBus Gateway
I/O Signal Details
Signal type
Bit
Signal
name
Description Details
PL
C
ou
tput
Control
signal
b7 -
Cannot
be
used.
-
b6 -
Cannot
be
used.
-
b5 -
Cannot
be
used.
-
b4
SON
Servo on command
6.2 (7)
b3 STP
Pause
command
6.2
(5)
b2
HOME
Home return command
6.2 (8)
b1 CSTR
Start
command
6.2
(9)
b0
RES
Reset command
6.2 (4)
Command
position
number
6-bit
data
(b5-0)
RC 32
~
PC1
Specify the command position number using a
binary value.*1
6.2 (11)
PLC inp
u
t
Status
signal
b7
EMGS
Emergency stop
6.2 (2)
b6 -
Cannot
be
used.
-
b5 PWR
Controller
ready
6.2
(1)
b4
SV
Ready (servo is on)
6.2 (7)
b3 MOVE
Moving
6.2
(6)
b2
HEND
Home return complete
6.2 (8)
b1 PEND
Positioning
complete
6.2
(10)
b0 ALM
Alarm
6.2
(3)
Zone signal
output 2
b7
ZONE2
*2
The completed position number and zone signal
status are output. Read the completed position
number as a six-bit binary value.
While an alarm is present (= the ALM signal is ON),
the content of the alarm is output to the completed
position number.
(For the contents of alarms that may be output,
refer to the table entitled “Alarm List” on the next
page.)
6.2 (13)
Zone signal
output 1
b6 ZONE1
Completed
position
number
(alarm
output)
6-bit
data
(b5-0)
PM32
~
PM1
6.2 (12)
*1 With the ERC2-NP/PN, up to 16 positioning points are supported in PIO control. If the gateway unit is
connected, however, up to 64 points can be specified.
*2 [ZONE2] is not supported by the ERC2-NP/PN.