78
9. Maintenance/Inspection
[3] Remove screws affixing guide covers R and L (2 pieces on each side). Slide the guide covers
horizontally to the opening side and remove. (Countersunk head screw M2 x 3)
Note: The cutout dimensions are different between guide covers R and L. Keep the removed guide covers
properly so that they will not be mixed up when installed.
[4] Use a flathead screwdriver to turn the
opening/closing screw on side cover L to move the
fingers toward the opening side.
[5] From the opening, spray grease over the feed screw at 2 locations through the springs (keep the
spray time to a maximum of 1 second). After spraying, turn the opening/closing screw to move the
fingers back and forth several times to spread the grease evenly.