Warning – IAI America RCP2W-GRLS User Manual
Page 85

75
9. Maintenance/Inspection
Finger
Finger guide
Open/close screw
Grease application
Cover
Small two-finger slide type (RCP2CR-GRSS)
9.4.2
Guide: Cleanroom Specification
(1) Applicable
grease
The following grease is applied to the feed screw before the gripper is shipped from the factory.
This is the grease that generates low dust.
Kuroda Precision Industries
C grease
Warning
x Never use a standard specification grease. This may generate dust.
x Never use a fluorine grease. If a fluorine grease is mixed with a lithium grease, chemical reaction may
take place and the machine may suffer damage.
(2)
How to apply grease
[Small Two-finger Slide Type (RCP2CR-GRSS)]
[Small Two-finger Lever Type (RCP2CR-GRLS)]
[1] In the case of small two-finger slide type
(RCP2CR-GRSS), remove the rubber cover.
Rubber covers have “notches” on them.
Detach the notches when removing the rubber
cover.
[2] Using a 2.5-mm Allen wrench, turn the
opening/closing screw at the center of the
fingers to move the fingers toward the stroke
center.
[3] With your finger, apply grease to the gap
between finger and finger guide (steel bearing).
After applying the grease, work it in by twisting
the opening/closing screw to move the finger
back and forth a few times. Remove excess
grease and grease spatters.