Installation, Safety instructions, Installation of the positioner type 8694 – Burkert Type 8694 User Manual
Page 32: On process valves of series 2103, 2300 and 2301
32
Installation
8.
INSTALLATION
8.1.
Safety instructions
DANGER!
Risk of injury from high pressure!
• Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.
Risk of electric shock!
• Before reaching into the device or the equipment, switch off the power supply and secure to prevent reactivation!
• Observe applicable accident prevention and safety regulations for electrical equipment!
WARNING!
Risk of injury from improper installation!
• Installation may be carried out by authorized technicians only and with the appropriate tools!
Risk of injury from unintentional activation of the system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.
8.2.
Installation of the positioner Type 8694
on process valves of series 2103, 2300 and 2301
Procedure:
1. Install switch spindle
Transparent cap
Actuator
Pilot air ports
(plug-in hose connectors with collets or
threaded bushings)
Figure 14:
Installation of the switch spindle (1), series 2103, 2300 and 2301
→
Unscrew the transparent cap on the actuator and unscrew the position display (yellow cap) on the spindle
extension (if present).
→
For version with plug-in hose connector, remove the collets (white nozzles) from both pilot air ports (if
present).
English
Type 8694