B&K Precision MDL Series - Programming Manual User Manual
Page 94

94
Table 1 - Error Numbers
Error
Error String [Description/Explanation/Examples]
Command Errors 100 through 199 (sets Standard Event Status Register bit #5 CME)
101
DESIGN ERROR: Too many numeric suffices in Command Spec
110
No Input Command to parse
114
Numeric suffix is invalid value
116
Invalid value in numeric or channel list, e.g. out of range
117
Invalid number of dimensions in a channel list
120
Parameter of type Numeric Value overflowed its storage
130
Wrong units for parameter
140
Wrong type of parameter(s)
150
Wrong number of parameters
160
Unmatched quotation mark (single/double) in parameters
165
Unmatched bracket
170
Command keywords were not recognized
180
No entry in list to retrieve (number list or channel list)
190
Too many dimensions in entry to be returned in parameters
191
Too many char
Execution Errors –200 through –299 (sets Standard Event Status Register bit #4 EXE)
-200
Execution error [generic]
-221
Settings conflict [check current device state]
-222
Data out of range [e.g., too large for this device]
-223
Too much data [out of memory; block, string, or expression too long]
-224
Illegal parameter value [device-specific]
-225
Out of memory
-270
Macro error
-272
Macro execution error
-273
Illegal macro label
-276