B&K Precision 8500-8526 - Manual User Manual
B&K Precision Equipment
Table of contents
Document Outline
- Safety
- Notation
- Quick reference
- Specifications
- Glossary
- Installation
- Inspection
- Instrument location
- Outline Drawings
- Bench operation
- First turn-on checkout
- Operational introduction
- Power-on state
- Constant current mode
- Constant voltage mode
- Constant power mode
- Constant resistance mode
- Timed operation
- Changing display resolution
- Short
- Battery test
- Transient operation
- Lists (dynamic condition)
- Test files
- Triggering
- Voltage threshold operation
- Passwords
- Protection features
- Remote sensing
- Saving and Recalling settings
- Remote operation
- Communication cables
- RS-232 settings
- Overview of DC Load programming
- Summary of commands
- Command details
- 0x12 Indicates a return packet for a command sent to the DC Load
- 0x20 Set the DC Load to remote operation
- 0x21 Turn the load ON or OFF
- 0x22 Set the maximum voltage allowed
- 0x23 Read the maximum voltage allowed
- 0x24 Set the maximum current allowed
- 0x25 Read the maximum current allowed
- 0x26 Set the maximum power allowed
- 0x27 Read the maximum power allowed
- 0x28 Set CC, CV, CW, or CR mode
- 0x29 Read the mode being used (CC, CV, CW, or CR)
- 0x2A Set CC mode current
- 0x2B Read CC mode current
- 0x2C Set CV mode voltage
- 0x2D Read CV mode voltage
- 0x2E Set CW mode power
- 0x2F Read CW mode power
- 0x30 Set CR mode resistance
- 0x31 Read CR mode resistance
- 0x32 Set CC mode transient current and timing
- 0x33 Read CC mode transient parameters
- 0x34 Set CV mode transient voltage and timing
- 0x35 Read CV mode transient parameters
- 0x36 Set CW mode transient power and timing
- 0x37 Read CW mode transient parameters
- 0x38 Set CR mode transient resistance and timing
- 0x39 Read CR mode transient parameters
- 0x3A Select the list operation (CC/CV/CW/CR)
- 0x3B Read the list operation (CC/CV/CW/CR)
- 0x3C Set how lists repeat (ONCE or REPEAT)
- 0x3D Read how lists repeat (ONCE or REPEAT)
- 0x3E Set the number of list steps
- 0x3F Read the number of list steps
- 0x40 Set one of the step's current and time values
- 0x41 Read one of the step's current and time values
- 0x42 Set one of the step's voltage and time values
- 0x43 Read one of the step's voltage and time values
- 0x44 Set one of the step's power and time values
- 0x45 Read one of the step's power and time values
- 0x46 Set one of the step's resistance and time values
- 0x47 Read one of the step's resistance and time values
- 0x48 Set the list file name
- 0x49 Read the list file name
- 0x4A Set the memory partitioning for storing lists
- 0x4B Read the memory partitioning for storing list steps
- 0x4C Save the list file
- 0x4D Recall the list file
- 0x4E Set minimum voltage in battery testing
- 0x4F Read minimum voltage in battery testing
- 0x50 Set timer value of for LOAD ON
- 0x51 Read timer value for LOAD ON
- 0x52 Disable/enable timer for LOAD ON
- 0x53 Read timer state for LOAD ON
- 0x54 Set communication address
- 0x55 Enable/disable LOCAL control
- 0x56 Enable/disable remote sensing
- 0x57 Read the state of remote sensing
- 0x58 Select trigger source
- 0x59 Read trigger source
- 0x5A Trigger the electronic load
- 0x5B Save DC Load's settings
- 0x5C Recall DC Load's settings
- 0x5D Select FIXED/SHORT/TRAN/LIST/BATTERY function
- 0x5E Get function type (FIXED/SHORT/TRAN/LIST/BATTERY)
- 0x5F Read input voltage, current, power and relative state
- 0x6A Get product's model, serial number, and firmware version
- 0x6B Read the bar code information
- Serial number and firmware version
- In case of trouble
- Appendix: Service and warranty information
- Index