This command is used to set series resistance when the load is in CZ mode.

Command Syntax [SOURce:]IMPedance:RESistance

Parameters 0 through 7500 ohms

Unit R (ohms)

*RST Value 0

Examples IMP:RES 5

Query Syntax [SOURce:]IMPedance:RESistance?

Returned Parameters

[SOURce:]IMPedance:INDuction

Channel Specific
This command is used to set the series inductance when the load is in CZ mode.

Command Syntax [SOURce:]IMPedance:INDuction

Parameters 0 through 65000uH

Unit uH

*RST Value 0

Examples IMP:IND 5

Query Syntax [SOURce:]IMPedance:INDuction?

Returned Parameters

[SOURce:]IMPedance:CAPacitance

Channel Specific
This command is used to set the parallel capacitance value when the load is in CZ mode.

Command Syntax [SOURce:]IMPedance:CAPacitance

Parameters 20 through 65000uF

Unit uF

Examples IMP:CAP 5

Query Syntax [SOURce:]IMPedance:CAPacitance?

Returned Parameters

[SOURce:]IMPedance:HIGH
[SOURce:]IMPedance:LOW

This command is used to set the high and low voltage determined when the load is in CZ mode.