B&K Precision MDL Series - Programming Manual User Manual
Page 59
59
Examples VOLT:HIGH 5
Query Syntax [SOURce:]VOLTage:HIGH?
[SOURce:]VOLTage:LOW?
[SOURce:]VOLTage:TRANsient:MODE
Channel Specific
This command selects the operating mode of the transient generator as follows in constant voltage
mode.
CONTinuous The transient generator puts out a continuous pulse stream after receipt of a trigger.
PULSe
The transient generator puts out a single pulse upon receipt of a trigger.
TOGGle
The transient generator toggles between two levels upon receipt of a trigger.
Command Syntax [SOURce:]VOLTage:TRANsient:MODE
Parameters CONTinuous | PULSe | TOGGle
*RST Value CONTinuous
Examples VOLT:TRAN:MODE PULS
Query Syntax [SOURce:] VOLTage:TRANsient:MODE?
Returned Parameters
Related Commands VOLT:TRAN:ALEV TRAN
[SOURce:]VOLTage:TRANsient:ALEVel
[SOURce:]VOLTage:TRANsient:BLEVel
Channel Specific
These commands specify the transient level of the input voltage. The transient function switches
between level A and level B.
Command Syntax [SOURce:]VOLTage:TRANsient:ALEVel
[SOURce:]VOLTage:TRANsient:BLEVel
Parameters 0 to max. rated voltage
Unit V (volts)
Examples VOLT:TRAN:ALEV 5 VOLT:TRAN:BLEV 0.5
Query Syntax [SOURce:]VOLTage:TRANsient:ALEVel?
[SOURce:]VOLTage:TRANsient:BLEVel?
Returned Parameters
Related Commands VOLT
[SOURce:]VOLTage:TRANsient:AWIDth