beautypg.com

B&K Precision MDL Series - Programming Manual User Manual

Page 59

background image

59

Examples VOLT:HIGH 5

Query Syntax [SOURce:]VOLTage:HIGH?

[SOURce:]VOLTage:LOW?

[SOURce:]VOLTage:TRANsient:MODE

Channel Specific
This command selects the operating mode of the transient generator as follows in constant voltage

mode.

CONTinuous The transient generator puts out a continuous pulse stream after receipt of a trigger.

PULSe

The transient generator puts out a single pulse upon receipt of a trigger.

TOGGle

The transient generator toggles between two levels upon receipt of a trigger.

Command Syntax [SOURce:]VOLTage:TRANsient:MODE

Parameters CONTinuous | PULSe | TOGGle

*RST Value CONTinuous

Examples VOLT:TRAN:MODE PULS

Query Syntax [SOURce:] VOLTage:TRANsient:MODE?

Returned Parameters

Related Commands VOLT:TRAN:ALEV TRAN

[SOURce:]VOLTage:TRANsient:ALEVel
[SOURce:]VOLTage:TRANsient:BLEVel

Channel Specific
These commands specify the transient level of the input voltage. The transient function switches

between level A and level B.

Command Syntax [SOURce:]VOLTage:TRANsient:ALEVel

[SOURce:]VOLTage:TRANsient:BLEVel

Parameters 0 to max. rated voltage

Unit V (volts)

Examples VOLT:TRAN:ALEV 5 VOLT:TRAN:BLEV 0.5

Query Syntax [SOURce:]VOLTage:TRANsient:ALEVel?

[SOURce:]VOLTage:TRANsient:BLEVel?

Returned Parameters

Related Commands VOLT

[SOURce:]VOLTage:TRANsient:AWIDth