Channel commands – B&K Precision MDL Series - Programming Manual User Manual
Page 36
36
Channel Commands
These commands program the channel selection capability of the electronic load. The CHANnel and
INSTrument commands are equivalent.
CHANnel
This command selects the multiple electronic load channels to which all subsequent channel-specific
commands will be directed. If the specified channel number does not exist or is outside the MIN/MAX
range, an error code is generated (see Chapter 5). Refer to the installation section of the User's Guide
for more information about channel number assignments. Channel 11-18 refers to channel 1-8 of
MDL002 extended mainframe.
Command Syntax CHANnel
Parameters 1-8, 11-18
*RST Value MINimum
Examples CHAN 3
Query Syntax CHANnel?
Returned Parameters
CHANnel:ID?
Channel Specific
This query reads the model numbers of the modules installed in the mainframe. It returns the data in
comma-separated fields.
Query Syntax CHANnel:ID?
Parameters None
Returned Parameters
Field
Information
xxxxxx
model number
xxxxxxxxxxxxxxxxxx serial number or 0
Verx.xx-x.xx
firmware revision
Example: MDL600, 600156010677530001, Ver1.35-1.20