Channel Commands

These commands program the channel selection capability of the electronic load. The CHANnel and

INSTrument commands are equivalent.


CHANnel

This command selects the multiple electronic load channels to which all subsequent channel-specific

commands will be directed. If the specified channel number does not exist or is outside the MIN/MAX

range, an error code is generated (see Chapter 5). Refer to the installation section of the User's Guide

for more information about channel number assignments. Channel 11-18 refers to channel 1-8 of

MDL002 extended mainframe.

Command Syntax CHANnel

Parameters 1-8, 11-18

*RST Value MINimum

Examples CHAN 3

Query Syntax CHANnel?

Returned Parameters

CHANnel:ID?

Channel Specific
This query reads the model numbers of the modules installed in the mainframe. It returns the data in

comma-separated fields.

Query Syntax CHANnel:ID?

Parameters None

Returned Parameters

Field

Information

xxxxxx

model number

xxxxxxxxxxxxxxxxxx serial number or 0

Verx.xx-x.xx

firmware revision

Example: MDL600, 600156010677530001, Ver1.35-1.20