B&K Precision MDL Series - Programming Manual User Manual
Page 62
62
[SOURce:]RESistance:HIGH
[SOURce:]RESistance:LOW
Channel Specific
This command is used to set the voltage high and low limit determined when the load is in constant
resistance mode.
Command Syntax [SOURce:]RESistance:HIGH
[SOURce:]RESistance:LOW
Parameters 0 to max. rated voltage
Unit V (volts)
Examples RES:HIGH 5
Query Syntax [SOURce:]RESistance:HIGH?
[SOURce:]RESistance:LOW?
Returned Parameters
[SOURce:]RESistance:TRANsient:MODE
Channel Specific
This command selects the operating mode of the transient generator as follows in constant resistance
mode.
CONTinuous The transient generator puts out a continuous pulse stream upon receipt of a trigger.
PULSe
The transient generator puts out a single pulse upon receipt of a trigger.
TOGGle
The transient generator toggles between two levels upon receipt of a trigger.
Command Syntax [SOURce:]RESistance:TRANsient:MODE
Parameters CONTinuous | PULSe | TOGGle
*RST Value CONTinuous
Examples RES:TRAN:MODE PULS
Query Syntax [SOURce:]RESistance:TRANsient:MODE?
Returned Parameters
Related Commands RES:TRAN:ALEV TRAN