B&K Precision MDL Series - Programming Manual User Manual
Page 69
69
This command sets the number of times that the list is executed before it is completed. The command
accepts parameters in the range 1 through 65536, but 65536 is interpreted as infinity.
Command Syntax [SOURce:]LIST:COUNt
Parameters 1 to 65536
Examples LIST:COUN 3
Query Syntax [SOURce:]LIST:COUNt?
Returned Parameters
Related Commands LIST:STEP
[SOURce:]LIST:STEP
Channel Specific
This command sets the total number of steps in the list.
Command Syntax [SOURce:]LIST:STEP
Parameters 2 to 84
Examples LIST:STEP 5
Query Syntax [SOURce:]LIST:STEP?
Returned Parameters
Related Commands LIST:LEV
[SOURce:]LIST:LEVel?
Channel Specific
This command specifies the level value
Command Syntax [SOURce:]LIST:LEVel
Parameters 1 to max. rated current.
Unit None, None
Examples LIST:LEV 1, 10 LIST:LEV 2, 15.2
Query Syntax [SOURce:]LIST:LEVel?
Returned Parameters
Related Commands LIST:RANG