B&K Precision MDL Series - Programming Manual User Manual
Page 76
76
Channel 18-11 represents channels 8 to 1 for MDL002
extended mainframe.
1 – channel will be shorted.
0 – channel will not be shorted.
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Channel 18 17 16 15 14 13 12 11 8
7
6
5
4
3
2
1
Examples PROG:SEQ:SHOR 683
683 = 1000100
Sets channel 3 and 7 for short testing.
Query Syntax PROG:SEQ:SHOR?
Returned Parameters
:PROGram:SEQuence:ONTime
The command is used to specify the input ON time for the selected sequence, which controls how long
to enable the inputs for the selected sequence.
Command Syntax PROGram:SEQuence:ONTime
Parameters
Examples PROG:SEQ:ONT 4, 5
Sets sequence 4 ON time to 5 seconds.
Query Syntax PROG:SEQ:ONT?
Returned Parameters
:PROGram:SEQuence:OFFTime
The command is used to specify the input OFF time for the selected sequence, which controls how long
to disable the inputs for the selected sequence.
Command Syntax PROGram:SEQuence:OFFTime
Parameters
Examples PROG:SEQ:OFFT 4, 5
Sets sequence 4 OFF time to 5 seconds.
Query Syntax PROG:SEQ:OFFT?
Returned Parameters