B&K Precision MDL Series - Programming Manual User Manual
Page 64
64
Command Syntax [SOURce:]POWer[:LEVel][:IMMediate]
Parameters 0 to max. rated power
Unit W (power)
*RST Value MINimum
Examples POW 5 POW:LEV 3.5
Query Syntax [SOURce:]POWer[:LEVel][:IMMediate]?
Returned Parameters
Related Commands POW:RANG
[SOURce:]POWer:RANGe
Channel Specific
This command sets the power range of the load. This limits the settable range for power.
Command Syntax [SOURce:]POWer:RANGe
Parameters 0 to max. rated power.
Unit W (power)
Examples POW:RANG 15 SOUR:POW:RANGE MIN
Query Syntax [SOURce:]POWer:RANGe?
Returned Parameters
[SOURce:]POWer:HIGH
[SOURce:]POWer:LOW
Channel Specific
This command sets the voltage high and low limit determined when in constant power mode.
Command Syntax [SOURce:]POWer:HIGH
[SOURce:]POWer:LOW
Parameters 0 to max. rated voltage
Unit V (volts)
Examples POW:HIGH 5
Query Syntax [SOURce:]POWer:HIGH? [SOURce:]POWer:LOW?
Returned Parameters