beautypg.com

B&K Precision MDL Series - Programming Manual User Manual

Page 64

background image

64

Command Syntax [SOURce:]POWer[:LEVel][:IMMediate]

Parameters 0 to max. rated power

Unit W (power)

*RST Value MINimum

Examples POW 5 POW:LEV 3.5

Query Syntax [SOURce:]POWer[:LEVel][:IMMediate]?

Returned Parameters

Related Commands POW:RANG


[SOURce:]POWer:RANGe

Channel Specific
This command sets the power range of the load. This limits the settable range for power.

Command Syntax [SOURce:]POWer:RANGe

Parameters 0 to max. rated power.

Unit W (power)

Examples POW:RANG 15 SOUR:POW:RANGE MIN

Query Syntax [SOURce:]POWer:RANGe?

Returned Parameters


[SOURce:]POWer:HIGH
[SOURce:]POWer:LOW

Channel Specific
This command sets the voltage high and low limit determined when in constant power mode.

Command Syntax [SOURce:]POWer:HIGH

[SOURce:]POWer:LOW

Parameters 0 to max. rated voltage

Unit V (volts)

Examples POW:HIGH 5

Query Syntax [SOURce:]POWer:HIGH? [SOURce:]POWer:LOW?

Returned Parameters