Query Syntax [SOURce:]CURRent:HIGH? [SOURce:]CURRent:LOW?
Returned Parameters
[SOURce:]VOLTage
Channel Specific
This command sets the voltage that the electronic load will regulate when operating in constant
voltage (CV) mode.
Command Syntax [SOURce:]VOLTage[:LEVel][:IMMediate]
Parameters See specifications for range
Unit V (volts)
Examples VOLT 5
Query Syntax [SOURce:]VOLTage[:LEVel][:IMMediate]?
Returned Parameters
Related Commands VOLT:RANG
[SOURce:]VOLTage:RANGe
Channel Specific
This command sets the voltage range of the electronic load module. There is only one voltage range.
Command Syntax [SOURce:] VOLTage:RANGe
Parameters see specifications for range
Unit V (volts)
Examples VOLT:RANG 15
Query Syntax [SOURce:]VOLTage:RANGe?
Returned Parameters
Related Commands VOLT
VOLTage:RANGe:AUTO
Channel Specific
This command sets the voltage auto range state of the electronic load module.
Command Syntax [SOURce:]VOLTage:RANGe:AUTO
Parameters 0 | 1 | ON | OFF
*RST Value 1