beautypg.com

B&K Precision MDL Series - Programming Manual User Manual

Page 32

background image

32

NOTE: The device state stored in location 0 is automatically recalled at power turn-on.

Command Syntax *RCL

Parameters 0 to 9

Example *RCL3

Related Commands *PSC *RST *SAV

*RST

This command resets ALL channels of the electronic load to the following factory-defined states:

CURR MIN

RES:TRAN:BLEV MIN

CURR:MODE FIX

RES:TRAN:BWID MIN

CURR:PROT:DEL 3

RES:TRAN:MODE CONT

CURR:PROT:LEV MAX

SENS:AVER:COUN 8

CURR:PROT:STAT OFF

SENS:AVER:STAT 1

CURR:RANG MAX

SENS:FUNC:CURR DC

CURR:SLEW MAX

SENS:NPLC 7

CURR:TRAN:ALEV MAX

SENS:VOLT:RANG:AUTO ON

CURR:TRAN:AWID MIN

TRAC:FEED TWO

CURR:TRAN:BLEV MIN

TRAC:FEED:MODE NEV

CURR:TRAN:BWID MIN

TRAC:POIN 2

CURR:TRAN:MODE CONT

TRAN OFF

FUNC CURR

TRIG:COUN 1

FUNC:MODE FIX

TRIG:DEL 0

INP OFF

VOLT MAX

INP:SHOR OFF

VOLT:ON MIN

POW:CONF MAX

VOLT:ON:LATC ON

POW:PROT:DEL 3

VOLT:RANG MAX

RES MAX

VOLT:TRAN:ALEV MAX

RES:RANG MAX

VOLT:TRAN:AWID MIN

RES:TRAN:ALEV MAX

VOLT:TRAN:BWID MIN

RES:TRAN:AWID MIN

VOLT:TRAN:MODE CONT