3.4 SCPI Command Tree

TRACe Command Summary

Commands

Description

Default

Channel

Specific

:TRACe

:CLEar

Clear readings from buffer.

Y

:FREE?

Query points available and points in use.

Y

:POINts

Specify size of buffer (2 to 1024).

2

Y

:POINts?

Query buffer size.

Y

:FEED

Select source of readings (VOLTage, CURRent,

TWO).

TWO

Y

:CONTrol

Select buffer control mode (NEVer or NEXT).

NEVer

Y

:CONTrol?

Query buffer control mode.

Y

:FEED?

Query source of readings for buffer.

Y

:FILTer

[:STATe]

Select the type of buffer data

OFF

[:STATe]?

Query the type of buffer data

:DELay

Set the trigger delay time

0

:DELay?

Query the trigger delay time

:TIMer

Set the timer interval

1

:TIMer?

Query the timer interval

:DATA?

Read all data in the buffer.

CHANnel Command Summary

Commands

Description

Default

Channel

Specific

:CHANnel

Select the electronic load channel.

1

:CHANel:ID?

This query reads the model numbers of the

modules installed in the mainframe.

Y