*RST Value 0.001

Examples TRIG:TIM 0.25 TRIG:TIM MAX

Query Syntax TRIGger:TIMer? [ MINimum | MAXimum | DEFault ]

Returned Parameters

Related Commands ABOR TRIG TRIG:SOUR TRIG:DEL


System Commands

System commands control the system-level functions of the electronic load that are not directly

related to input control or measurement functions.

SYSTem:PRESet

This command returns the instrument to states optimized for front panel operation.

Command Syntax SYSTem:PRESet

Parameters None

SYSTem:POSetup

This command is used to select the power-on defaults. With RST selected, the instrument powers up to

the *RST default conditions. With the SAV0 parameter selected, the instrument powers-on to the

setup that is saved in the specified location using the *SAV command.

Command Syntax SYSTem:POSetup

Parameters RST | SAV0

*RST Value RST

Examples SYST:POS RST

Query Syntax SYSTem:POSetup?

Returned Parameters

Related Commands *RST *SAV

SYSTem:VERSion?

This query returns the SCPI version number to which the electronic load complies. The value is of the

form YYYY.V, where YYYY is the year and V is the revision number for that year.

Query Syntax SYSTem:VERSion?

Parameters None