Stormflow conditional

Use this window to set the way stormflow detection and
recording will operate.

Start time

Select how many minutes the first spill must be above the
set limit before it is accepted as a stormflow.

Stop timeout

Select how many minutes the level must be below the set
limit before it is accepted as a terminated stormflow.

Start volume

Enter how many litres litres the first spill must contain
before it is accepted as a stormflow.

Signal name

Select an existing signal name or enter a new signal name.

The signal name will act as an identifier for this input, inserted into any SMS messages and e-mails sent
from this Chatter™ Data Logger