Rainbow Electronics DS2152 User Manual
Page 54
DS2152
031897 54/79
C5
TCD.5
Transmit Code Definition Bit 5.
C4
TCD.4
Transmit Code Definition Bit 4.
C3
TCD.3
Transmit Code Definition Bit 3.
C2
TCD.2
Transmit Code Definition Bit 2. A Don’t Care if a 5 bit length is selected.
C1
TCD.1
Transmit Code Definition Bit 1. A Don’t Care if a 5 or 6 bit length is
selected.
C0
TCD.0
Transmit Code Definition Bit 0. A Don’t Care if a 5, 6 or 7 bit length is
selected.
RUPCD: RECEIVE UP CODE DEFINITION REGISTER (Address=14 Hex)
(MSB)
(LSB)
C7
C6
C5
C4
C3
C2
C1
C0
SYMBOL
POSITION
NAME AND DESCRIPTION
C7
RUPCD.7
Receive Up Code Definition Bit 7. First bit of the repeating pattern.
C6
RUPCD.6
Receive Up Code Definition Bit 6. A Don’t Care if a 1 bit length is
selected.
C5
RUPCD.5
Receive Up Code Definition Bit 5. A Don’t Care if a 1 or 2 bit length is
selected.
C4
RUPCD.4
Receive Up Code Definition Bit 4. A Don’t Care if a 1 to 3 bit length is
selected.
C3
RUPCD.3
Receive Up Code Definition Bit 3. A Don’t Care if a 1 to 4 bit length is
selected.
C2
RUPCD.2
Receive Up Code Definition Bit 2. A Don’t Care if a 1 to 5 bit length is
selected.
C1
RUPCD.1
Receive Up Code Definition Bit 1. A Don’t Care if a 1 to 6 bit length is
selected.
C0
RUPCD.0
Receive Up Code Definition Bit 0. A Don’t Care if a 1 to 7 bit length is
selected.
RDNCD: RECEIVE DOWN CODE DEFINITION REGISTER (Address=15 Hex)
(MSB)
(LSB)
C7
C6
C5
C4
C3
C2
C1
C0
SYMBOL
POSITION
NAME AND DESCRIPTION
C7
RDNCD.7
Receive Down Code Definition Bit 7. First bit of the repeating pattern.
C6
RDNCD.6
Receive Down Code Definition Bit 6. A Don’t Care if a 1 bit length is
selected.
C5
RDNCD.5
Receive Down Code Definition Bit 5. A Don’t Care if a 1 or 2 bit length is
selected.